The following commands to change parameters are found on the Video Monitoring Software Program Administration web page under the heading, Video Settings.
Set Video Image Size(320,160)
Only two possible values to enter 320, 160. 320=320x240 size image. 160=160x120 size image. Place in Desk Mode first. Set parameter, save configuration. Set for Web Mode and save configuration. Re-start the Program. Will work only if, setting Enable Program to Change Video Parameters, is enabled.
Set Number of Capture Files(2-1M)
Can be set from 2 to 1000000. Determines the number of video files Video Monitoring Software is allowed to create, and no more are allowed. As it monitors and saves, it DELETES the oldest video file automatically to make room for a new video file, so as to not exceed specified value. Range 2-1000000.
Set Sensitivity(0-19200)
A value of 80-200 is typical. The larger the value the less is detected. The smaller the value more motion is detected. If image size is 320x240 range is 76,800. If image size is 160x120 range is 19200.
Set Threshold(0-65535)
A value of 80 is typical. The larger the value less light passes through and less detection, the smaller the value more light passes through for image creation and more detection. If using 16 bpp resolution 2000 may be typical.